MENU

Flooring Installation Quick Check Plus Kit - IQCPK

Check concrete moisture levels before installing flooring

QUICK CHECK PROCEDURE AT TIME OF INSTALL

The Tramex IQCPK is a compact kit for conducting the Installation Quick Check test, which is the instant, non-destructive, quantitative moisture content testing of concrete floors and ambient dew-point conditions at the time of installation. 

Even if pre-installation tests have been performed, checking the %MC and ambient dew-point conditions at the time of installation is crucial to ensure successful installation. The Tramex CMEX5 digital moisture meter allows for non-destructive quantitative testing of concrete moisture content using Gravimetric testing as a baseline. The CMEX5 has a built-in hygrometer providing ambient relative humidity, temperature and dew-point measurements. The Infrared Thermometer provides surface temperature readings for comparison with the dew-point conditions to avoid condensation-related issues at the time of installation and floor failures. The Tramex Meters App allows for data reporting to mobile devices, to GeoTag test results, create, save and share photos, reports and charts. The Tramex Flooring Installation Quick Check Plus Kit comes in a Tramex Easy-travel case.

Product Order Code: IQCPK

	 
	

		
		


		  
	
	
	
	
	
	

	

		
		


		  
	
	
	
	
	
	

	
		
	
	
	
	
	
	
































 
	

Concrete Moisture Encounter X5 - CMEX5 - Measuring Range:  

Depth of penetration in concrete: approx.  ¾" (20mm)
Moisture content for Concrete: 0 → 6.9 %
Comparative for Gypsum floor screed: 0 → 12
CM Equiv Anhydrite/Concrete: 0→2.7 / 0→4.3
Reference scale: 0 → 100
Relative Humidity: 0 → 99%
(with optional Hygro-i2 ® probe): Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): 5 → 30 %

 

Infrared Thermometer  IRT2

Temperature range: -58ºF ~ 1202ºF (-50 to 650 ºC)
Distance to Spot ratio: D:S = 12:1
Display resolution: 0.1 ºF(0.1ºC)   <1000 1ºC   >1000
Accuracy for targets:

Assumes ambient operating temperature of  73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC) 

±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC)  ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5%

Repeatability: -58~68ºF (-50~20ºC)  :  ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC)
Response time: 150ms
Spectral response: 8~14um
Emissivity: Digitally adjustable from 0.10 to 1.0
Over range indication: LCD will show “----”
Polarity: Automatic (no indication for positive polarity); Minus (-) sign for negative polarity
Diode laser output: <1mW,Wavelength 630~670nm, Class 2 laser product
Operating temp.: 32 to 122ºF ( 0 to 50ºC)
Storage temp.: 14 to 140ºF (–10 to 60ºC)
Relative humidity: 10%~90%RH operating, <80%RH storage
Power supply: 9V battery, NEDA 1604A or IEC 6LR61, or equivalent
Safety: “ CE ” Comply with EMC

 

Specifications of Kit:

Size: 13.8” x 9.1” x 3.5” (35cm x 23cm x 90cm)
Weight: 2.8lbs (1.3kg)
Power: 2 x AA batteries, 1 x 9 volt PP3 battery

Related Products

Calibration Check Plate

Calibration Check Plate

Calibration Check Plate for Tramex CME5CMEX5, CME4 and CMEX2. The calibration check plate allows for regular on-site calibration checks.