The Tramex CCIK is an excellent kit for checking moisture in concrete for instant, non-destructive, quantitative moisture content testing of concrete floors and ambient conditions and is the ideal non-destructive test kit for monitoring the most crucial information at the time of application.
The Tramex CMEX5 digital moisture meter allows for non-destructive quantitative testing of concrete using Gravimetric testing as a baseline and comparative testing per ASTM F2659. Non-destructive testing of the top ¾” of the slab is most critical when applying coatings. An infrared surface thermometer gives surface temperature and dew point conditions used in conjunction with the Tramex CMEX5 built-in hygrometer.
The Tramex Concrete Coatings Inspector Kit comes with an extension handle in a heavy-duty Tramex travel case. Bluetooth connectivity to the Tramex Meters App allows for visualization of readings and data reporting to mobile devices, to GeoTag test results, create, save and share photos, reports and charts, as well as see your meter screen on your phone when extending to hard to reach places.
Concrete Moisture Encounter X5 - CMEX5 - Measuring Range:
Depth of penetration in concrete: | approx. ¾" (20mm) |
Moisture content for Concrete: | 0 → 6.9 % |
Comparative for Gypsum floor screed: | 0 → 12 |
CM Equiv Anhydrite/Concrete: | 0→2.7 / 0→4.3 |
Reference scale: | 0 → 100 |
Relative Humidity: | 0 → 99% |
(with optional Hygro-i2 ® probe): | Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F |
Moisture content for wood (with optional wood pin probes): | 5 → 30 % |
Infrared Thermometer IRT2
Temperature range: | -58ºF ~ 1202ºF (-50 to 650 ºC) |
Distance to Spot ratio: | D:S = 12:1 |
Display resolution: | 0.1 ºF(0.1ºC) <1000 1ºC >1000 |
Accuracy for targets: |
Assumes ambient operating temperature of 73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC) ±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC) ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5% |
Repeatability: | -58~68ºF (-50~20ºC) : ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC) |
Response time: | 150ms |
Spectral response: | 8~14um |
Emissivity: | Digitally adjustable from 0.10 to 1.0 |
Over range indication: | LCD will show “----” |
Polarity: | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity |
Diode laser output: | <1mW,Wavelength 630~670nm, Class 2 laser product |
Operating temp.: | 32 to 122ºF ( 0 to 50ºC) |
Storage temp.: | 14 to 140ºF (–10 to 60ºC) |
Relative humidity: | 10%~90%RH operating, <80%RH storage |
Power supply: | 9V battery, NEDA 1604A or IEC 6LR61, or equivalent |
Safety: | “ CE ” Comply with EMC |
Specifications of Kit:
Size: | 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm) |
Weight: | 6.8 lbs (3.1kg) |
Power: | 2 x AA batteries, 1 x 9 volt PP3 battery |